Vendor-neutral, governed industrial/OT data tap + intelligent troubleshooting. Read (and, gated, write) PLCs, controllers, machine tools and IIoT brokers over OPC-UA, Modbus-TCP, Siemens S7comm, Mitsubishi MC, Omron FINS, MTConnect, MQTT/Sparkplug B, Allen-Bradley EtherNet/IP, EtherCAT (pysoem/SOEM), SECS/GEM (semiconductor / display fab equipment over HSMS), PROFINET (DCP discovery), the building edition (BACnet/IP), and Phoenix Contact PLCnext vPLC — plus cross-protocol diagnostics ("no-data" dataflow diagnosis, OPC-UA connection self-diagnosis, subscription health, ISA-18.2 alarm bad-actors, tag/historian health, and the AI downtime root-cause copilot) and analytics (OEE/downtime, asset inventory, OPC-UA HDA, change-of-value). Use when the task names any industrial protocol, a PLC/SCADA/HMI/historian/CNC/RTU/IED, a semiconductor/display fab or SECS/GEM equipment, an electrical substation, an opc.tcp:// or mqtt:// endpoint, OEE/downtime, downtime root-cause, or OT asset inventory. Ro
数据分析
iaiops-fab
试用Fab edition of iaiops — semiconductor / display (panel TFT-LCD/OLED) fab equipment over SECS/GEM (SEMI E5 SECS-II, E30 GEM, E37 HSMS) plus OPC-UA for the equipment's internal control layer, with the cross-protocol brain (downtime root-cause copilot, OEE, asset inventory, data quality). Use when the task mentions SECS/GEM, SECS-II, HSMS, GEM host, wafer, panel, fab equipment, MES equipment interface, SVID, ECID, ALID, PPID / process program, recipe list, or a semiconductor / display fab tool. Read-first, MOC-gated writes.
它能做什么
Fab edition of iaiops — semiconductor / display (panel TFT-LCD/OLED) fab equipment over SECS/GEM (SEMI E5 SECS-II, E30 GEM, E37 HSMS) plus OPC-UA for the equipment's internal control layer, with the cross-protocol brain (downtime root-cause copilot, OEE, asset inventory, data quality). Use when the task mentions SECS/GEM, SECS-II, HSMS, GEM host, wafer, panel, fab equipment, MES equipment interface, SVID, ECID, ALID, PPID / process program, recipe list, or a semiconductor / display fab tool. Read-first, MOC-gated writes.
技能文档
iaiops-fab — 半导体/显示 fab edition(SECS/GEM + OPC-UA + 脑)
启动:IAIOPS_MCP=fab / iaiops-mcp-fab(暴露 secsgem + opcua + s7 + modbus + 脑)。
安装:pip install iaiops[fab]。我们是 HOST(HSMS ACTIVE),设备是 equipment。
Fab 分层认知:一台 fab 设备是两层 —— MES-facing 的 SECS/GEM(HSMS) 接口,与 设备内部控制(PLC,走 OPC-UA/S7/Modbus)。职责不同,别混。S7/Modbus 工具清单见 iaiops-factory skill(fab profile 已同时暴露)。
工具
SECS/GEM(只读;设备 ↔ MES 标准,fab 入场券)
secsgem_equipment_status— 建立 GEM 链路 + Are-You-There(S1F1/F2)secsgem_list_status_variables— SVID namelist(S1F11/F12)secsgem_read_status_variables— SVID 值(S1F3/F4)secsgem_list_equipment_constants— ECID namelist(S2F29/F30)secsgem_read_equipment_constants— ECID 值(S2F13/F14)secsgem_list_alarms— 告警表(S5F5/F6):ALID、ALCD、textsecsgem_list_process_programs— PPID 目录(S7F19/F20)
OPC-UA(只读;设备内控层 / opc.tcp 端点)
opcua_server_info/opcua_browse/opcua_read_node/opcua_read_manyopcua_subscribe_sample— 有界采样后返回(绝不死循环)opcua_read_alarms— best-effort 活动告警/condition(untimed);opcua_alarm_events— A&C 事件订阅(带服务器时间戳)opcua_read_history— HDA 历史读取([start,end] 窗口)opcua_diagnose_connection— 连不上时归因(证书/安全策略/认证/防火墙/DNS/端口/配置)opcua_discover_tags— 自动发现 tag 并建语义资产模型opcua_health_summary— tag vs 阈值分类;opcua_anomaly_scan— 有界统计异常扫描
Fab / 质量专属(edition 工具;仅随 fab edition 加载,不进全局脑)
spc_check— 统计过程控制:对一段量测序列套用 Western Electric / Nelson 控制图规则 (越 3σ、2/3 越 2σ、4/5 越 1σ、连续 8 点单侧、6 点趋势),逐条按点索引报违规;给 USL/LSL 则附 Cp/Cpk。判 in_control / out_of_control。纯分析,每违规引用触发点索引。defect_pareto— 缺陷帕累托:按缺陷类别计数排序,算各类占比与累计占比,标出到 80% 线的 关键少数(遏制/改善最有杠杆的类别)。纯分析,喂检验/缺陷记录,每占比引用计数。
跨协议脑(永远随 server 暴露)
- 诊断:
diagnose_dataflowdowntime_root_causedowntime_root_cause_livedowntime_triagelearn_cause_weightsrca_corpus_from_maintenancehistorian_healthalarm_bad_actorstag_healthsubscription_healthheartbeat_healthalarm_flood_analysisalarm_cascadealarm_rationalization_worksheet - 数据质量:
data_quality_scorecarddata_quality_fleet_rollup - 分析:
oee_computedowntime_eventsoee_multidimmonitor_changeshealth_summary(deprecated)anomaly_scan(deprecated) - 资产:
asset_inventorycross_protocol_asset_modeladopt_alias_mapdiff_alias_map - 基线:
baseline_learnbaseline_checkbaseline_record_changebaseline_status(change-log 基线:拒学薄历史、只报持续越带、每次告警必引基线样本 —— 非黑盒异常检测) - 合规/信创:
compliance_mappingcompliance_frameworkscompliance_dengbao_levelscompliance_reportcompliance_evidence_bundlehistorian_pushexport_datahistorian_queryhistorian_coveragestream_publishstream_publish_eventrca_narratefleet_statusfleet_incidentspdm_forecasthistorian_pushexport_data - 程序解读:
plc_program_outlineplc_program_xrefplc_program_sectionplc_program_visibility(解读导出的 ST/AWL/L5X 程序,只读文件,强制引用行号) - 元:
protocols_supported
Workflows
- Doctor-first:
protocols_supported看配置 →iaiops doctor探活 →secsgem_equipment_status确认 GEM 链路(S1F1/F2 通了再谈其他)。 - Read-first:SVID/ECID namelist → 值 →
secsgem_list_alarms;PLC 层用 OPC-UA 工具;停机问题直接downtime_root_cause_live(advisory,引用真实信号)。 - MOC 写:本 edition 的 SECS/GEM 与 OPC-UA 工具均只读;fab profile 暴露的写工具
(如
s7_write_db)走统一 MOC:risk=HIGH+ 默认dry_run=True+ 改前值 undo + 具名审批人iaiops approve双确认。未经授权绝不写生产设备。
支持版本矩阵(内部 HLD §8,设计文档不随本仓发布;待核实 不得当既成事实)
| 协议 | 库(pin) | 规范/版本 | 覆盖 | 传输 | 自测 |
|---|---|---|---|---|---|
| SECS/GEM | secsgem>=0.3,<1 | SECS-II(E5) · GEM(E30) · HSMS(E37/TCP);SECS-I(E4) 待核实 | 面板/半导体设备 ↔ MES(HOST 侧) | HSMS/TCP | ✅ host+equipment 全软件自测;真机 待核实 |
| OPC-UA | asyncua>=2.0,<3 | OPC UA 1.0x(DA+HA+AC 子集);FX/TSN 在路线 | 任意合规 Server | opc.tcp | ✅ mock+HDA |
相关技能
Factory edition of iaiops — discrete-manufacturing lines: OPC-UA, Modbus-TCP/RTU, Siemens S7comm (S7-300/400/1200/1500), Mitsubishi MC/MELSEC, Omron FINS (CS/CJ/CP/NX), Allen-Bradley EtherNet/IP (ControlLogix/CompactLogix), EtherCAT (CoE/SOEM), PROFINET (DCP discovery), MTConnect (CNC machine tools), IO-Link (master JSON — sensor-level visibility), MQTT/Sparkplug B/UNS, plus the cross-protocol brain (downtime root-cause, OEE, asset inventory). Use for PLC, CNC, servo/drive bus, name-of-station, tag browse, Unified Namespace, or production-line troubleshooting tasks. Read-first, MOC-gated writes. Also covers Phoenix Contact PLCnext vPLC (via its built-in OPC-UA + Modbus servers).
Process-industry edition of iaiops — chemical / pharma / food & beverage / oil & gas plants: HART-IP process instrumentation (transmitters, valve positioners, loop current), OPC-UA (DCS / gateway read), Modbus-TCP/RTU (skids, analyzers), optional MQTT/Sparkplug B UNS, plus the cross-protocol brain (downtime root-cause, data quality, OEE). Use when the task mentions HART, HART-IP, transmitter, 变送器, valve positioner, process instrumentation, PV/SV/TV/QV, loop current, burst mode, DCS tap, or a process plant. Read-first, MOC-gated writes.
Building edition of iaiops — facility / HVAC / BMS / 厂务 over BACnet/IP (ASHRAE 135): Who-Is discovery, object/point lists, presentValue snapshots, COV capture, TrendLog reads, one MOC-gated property write; plus Modbus-TCP/RTU for meters/chillers and optional plain MQTT for IoT sensors, with the cross-protocol brain. Use when the task mentions BACnet, BACnet-IP, HVAC, AHU, chiller, VAV, BMS, building automation, facility management, 厂务, 楼宇自控, Who-Is, presentValue, or TrendLog; also IO-Link masters for smart building sensors (JSON interface, read-only), and the vendor supervisory-controller REST layer above BACnet (Metasys/OpenBlue, Niagara/oBIX) for point/alarm/trend reads and one MOC-gated command. Read-first, MOC-gated writes.
Warehouse / intralogistics edition of iaiops — distribution centers, fulfillment, material handling: conveyors, sorters, palletizers, AS/RS, and AGV/AMR fleets. EtherNet/IP (Allen-Bradley / Rockwell conveyor & sorter PLCs), Profinet (Siemens material-handling lines), Modbus (VFDs / energy meters, with conveyor_vfd & agv_battery templates), OPC-UA (WMS/WCS gateways), and MQTT-Sparkplug (AMR / IoT telemetry) — plus the cross-protocol brain: predictive maintenance (pdm_forecast for conveyor-drive bearing/thermal trend), downtime triage, OEE/throughput, and alarm analysis. Use when the task mentions warehouse, 仓储, 物流, intralogistics, distribution center / DC, fulfillment, conveyor / 输送线, sorter / 分拣, palletizer, AS/RS / 立体库, AGV / AMR / 移动机器人, WMS / WCS, or material handling. Read-first; this edition's tool surface is read-only.
Water-treatment edition of iaiops — waterworks / wastewater plants / pump stations: Modbus-TCP/RTU (dosing skids, analyzers, flow meters), OPC-UA (plant SCADA / PLC read), HART-IP process instrumentation (pH, turbidity, conductivity, level, flow transmitters), plus the cross-protocol brain (downtime root-cause, data quality watchdog, OEE). Use when the task mentions water treatment, 水处理, 水厂, 污水, pH, 浊度, turbidity, 电导率, conductivity, dissolved oxygen, 加药, dosing pump, 泵站, pump station, aeration / 曝气, or lift station. Read-first; this edition's tool surface is read-only.