Water-treatment edition of iaiops — waterworks / wastewater plants / pump stations: Modbus-TCP/RTU (dosing skids, analyzers, flow meters), OPC-UA (plant SCADA / PLC read), HART-IP process instrumentation (pH, turbidity, conductivity, level, flow transmitters), plus the cross-protocol brain (downtime root-cause, data quality watchdog, OEE). Use when the task mentions water treatment, 水处理, 水厂, 污水, pH, 浊度, turbidity, 电导率, conductivity, dissolved oxygen, 加药, dosing pump, 泵站, pump station, aeration / 曝气, or lift station. Read-first; this edition's tool surface is read-only.
Design & media
iaiops-renewables
Try itRenewables edition of iaiops — solar PV plants and wind farms: PV inverters / string combiners and wind-turbine controllers over Modbus (SUN2000 / Growatt / generic wind-turbine templates), plant SCADA over OPC-UA, and MQTT-Sparkplug telemetry, plus the cross-protocol brain (PdM, downtime, OEE, alarm) and a renewables signature tool pv_performance (underperforming-string detection). Use when the task mentions solar / 光伏 / PV / photovoltaic, inverter / 逆变器 / 组串 / string / combiner, irradiance / 辐照 / POA, wind / 风电 / turbine / 风机 / nacelle / pitch / yaw, plant SCADA, performance ratio, soiling / 积灰 / shading / 遮挡, or 电站. Read-first; this edition's tool surface is read-only.
What it does
Renewables edition of iaiops — solar PV plants and wind farms: PV inverters / string combiners and wind-turbine controllers over Modbus (SUN2000 / Growatt / generic wind-turbine templates), plant SCADA over OPC-UA, and MQTT-Sparkplug telemetry, plus the cross-protocol brain (PdM, downtime, OEE, alarm) and a renewables signature tool pv_performance (underperforming-string detection). Use when the task mentions solar / 光伏 / PV / photovoltaic, inverter / 逆变器 / 组串 / string / combiner, irradiance / 辐照 / POA, wind / 风电 / turbine / 风机 / nacelle / pitch / yaw, plant SCADA, performance ratio, soiling / 积灰 / shading / 遮挡, or 电站. Read-first; this edition's tool surface is read-only.
The skill document
iaiops-renewables — 光伏 / 风电 edition(Modbus + OPC-UA + Sparkplug + 脑)
启动:IAIOPS_MCP=renewables / iaiops-mcp-renewables(= modbus + opcua + sparkplug
- 脑;等价
IAIOPS_MCP=modbus,opcua,sparkplug)。典型现场:逆变器/组串汇流箱、风机控制器 走 Modbus,全站 SCADA 走 OPC-UA,遥测经 MQTT-Sparkplug。语义层已含 irradiance / wind_speed / rotor_speed / pitch / yaw / state_of_charge 等可再生类别(opcua_discover_tags自动归类)。
工具
可再生专属(edition 工具;仅随 renewables edition 加载,不进全局脑)
pv_performance— 组串/逆变器欠发检测:算各组串性能比(有expected_w用之,或 额定×辐照/1000,否则对全场中位数),低于阈值即 underperforming(积灰/遮挡/熔丝断/组件失效), ~0 功率为 offline。worst-first,每比值引用输入。纯分析,喂逆变器/汇流箱 Modbus 或站 SCADA。
Modbus-TCP / RTU(只读;逆变器、汇流箱、风机控制器、表计)
modbus_read_holdingmodbus_read_inputmodbus_read_coilsmodbus_read_discretemodbus_detect_byte_order— 字节/字序自动探测modbus_list_templates/modbus_apply_template— 厂商模板 → 命名 tag (可再生模板:huawei_sun2000_inverter、growatt_inverter、generic_wind_turbine;均待核实)modbus_health_summary— 寄存器 vs 阈值分类
OPC-UA(只读;全站 SCADA / PLC 网关)
opcua_server_info/opcua_browse/opcua_read_node/opcua_read_manyopcua_subscribe_sampleopcua_read_alarmsopcua_alarm_events(A&C 带时间戳)opcua_read_history(HDA)opcua_diagnose_connectionopcua_discover_tagsopcua_health_summaryopcua_anomaly_scan
MQTT-Sparkplug B(可选;电站遥测 / IoT 网关 UNS)
sparkplug_node_listsparkplug_subscribe_samplesparkplug_decode_payloadmqtt_read_topicmqtt_publishsparkplug_live_schemauns_browseuns_topic_audituns_schema_driftuns_live_audituns_live_drift
跨协议脑(永远随 server 暴露)
- 诊断:
diagnose_dataflowdowntime_root_causedowntime_root_cause_livedowntime_triagelearn_cause_weightsrca_corpus_from_maintenancehistorian_healthalarm_bad_actorstag_healthsubscription_healthheartbeat_healthalarm_flood_analysisalarm_cascadealarm_rationalization_worksheet - 预测维护:
pdm_forecast—— 逆变器温升、风机轴承/齿轮箱趋势 + 到限时间 - 数据质量:
data_quality_scorecarddata_quality_fleet_rollup - 分析:
oee_computedowntime_eventsoee_multidimmonitor_changes - 资产:
asset_inventorycross_protocol_asset_modeladopt_alias_mapdiff_alias_map - 基线:
baseline_learnbaseline_checkbaseline_record_changebaseline_status - 合规/信创:
compliance_mappingcompliance_frameworkscompliance_dengbao_levelscompliance_reportcompliance_evidence_bundlehistorian_pushexport_datahistorian_queryhistorian_coveragestream_publishstream_publish_eventrca_narratefleet_statusfleet_incidents - 程序解读:
plc_program_outlineplc_program_xrefplc_program_sectionplc_program_visibility - 元:
protocols_supported
Workflows
- Doctor-first:
protocols_supported→iaiops doctor→ OPC-UA 先opcua_diagnose_connection。 - 欠发排查:
modbus_apply_template(huawei_sun2000_inverter) 读各组串功率(+辐照) →pv_performance排欠发组串 → 结合pdm_forecast盯逆变器温升趋势。 - 停机/告警:
downtime_triage;风机齿轮箱/轴承劣化用pdm_forecast。 - 只读:本 edition 工具表面全只读(逆变器限功率/风机偏航不经本工具下发)。
支持版本矩阵(内部 HLD §8,设计文档不随本仓发布;待核实 不得当既成事实)
| 协议 | 库(pin) | 规范/版本 | 覆盖 | 传输 | 自测 |
|---|---|---|---|---|---|
| Modbus-TCP | pymodbus>=3.5,<4 | App 1.1b3;FC 1/2/3/4/5/6/15/16 | 逆变器/汇流箱/风机/表计 | TCP/502 | ✅ |
| Modbus-RTU | pymodbus>=3.5,<4 + pyserial>=3.5 | Modbus serial (RTU) | 串口从站/表计 | RS-485/serial | ✅ socat PTY;物理 RS-485 待核实 |
| OPC-UA | asyncua>=2.0,<3 | OPC UA 1.0x(DA+HA+AC 子集) | 全站 SCADA / PLC 网关 | opc.tcp | ✅ mock+HDA |
| MQTT-Sparkplug B | paho-mqtt>=2.0,<3(extra) | Sparkplug B 3.0 | 电站遥测 / IoT 网关 UNS | MQTT/1883/8883 | ✅ broker mock |
Related skills
Process-industry edition of iaiops — chemical / pharma / food & beverage / oil & gas plants: HART-IP process instrumentation (transmitters, valve positioners, loop current), OPC-UA (DCS / gateway read), Modbus-TCP/RTU (skids, analyzers), optional MQTT/Sparkplug B UNS, plus the cross-protocol brain (downtime root-cause, data quality, OEE). Use when the task mentions HART, HART-IP, transmitter, 变送器, valve positioner, process instrumentation, PV/SV/TV/QV, loop current, burst mode, DCS tap, or a process plant. Read-first, MOC-gated writes.
Building edition of iaiops — facility / HVAC / BMS / 厂务 over BACnet/IP (ASHRAE 135): Who-Is discovery, object/point lists, presentValue snapshots, COV capture, TrendLog reads, one MOC-gated property write; plus Modbus-TCP/RTU for meters/chillers and optional plain MQTT for IoT sensors, with the cross-protocol brain. Use when the task mentions BACnet, BACnet-IP, HVAC, AHU, chiller, VAV, BMS, building automation, facility management, 厂务, 楼宇自控, Who-Is, presentValue, or TrendLog; also IO-Link masters for smart building sensors (JSON interface, read-only), and the vendor supervisory-controller REST layer above BACnet (Metasys/OpenBlue, Niagara/oBIX) for point/alarm/trend reads and one MOC-gated command. Read-first, MOC-gated writes.
Factory edition of iaiops — discrete-manufacturing lines: OPC-UA, Modbus-TCP/RTU, Siemens S7comm (S7-300/400/1200/1500), Mitsubishi MC/MELSEC, Omron FINS (CS/CJ/CP/NX), Allen-Bradley EtherNet/IP (ControlLogix/CompactLogix), EtherCAT (CoE/SOEM), PROFINET (DCP discovery), MTConnect (CNC machine tools), IO-Link (master JSON — sensor-level visibility), MQTT/Sparkplug B/UNS, plus the cross-protocol brain (downtime root-cause, OEE, asset inventory). Use for PLC, CNC, servo/drive bus, name-of-station, tag browse, Unified Namespace, or production-line troubleshooting tasks. Read-first, MOC-gated writes. Also covers Phoenix Contact PLCnext vPLC (via its built-in OPC-UA + Modbus servers).
Vendor-neutral, governed industrial/OT data tap + intelligent troubleshooting. Read (and, gated, write) PLCs, controllers, machine tools and IIoT brokers over OPC-UA, Modbus-TCP, Siemens S7comm, Mitsubishi MC, Omron FINS, MTConnect, MQTT/Sparkplug B, Allen-Bradley EtherNet/IP, EtherCAT (pysoem/SOEM), SECS/GEM (semiconductor / display fab equipment over HSMS), PROFINET (DCP discovery), the building edition (BACnet/IP), and Phoenix Contact PLCnext vPLC — plus cross-protocol diagnostics ("no-data" dataflow diagnosis, OPC-UA connection self-diagnosis, subscription health, ISA-18.2 alarm bad-actors, tag/historian health, and the AI downtime root-cause copilot) and analytics (OEE/downtime, asset inventory, OPC-UA HDA, change-of-value). Use when the task names any industrial protocol, a PLC/SCADA/HMI/historian/CNC/RTU/IED, a semiconductor/display fab or SECS/GEM equipment, an electrical substation, an opc.tcp:// or mqtt:// endpoint, OEE/downtime, downtime root-cause, or OT asset inventory. Ro
Warehouse / intralogistics edition of iaiops — distribution centers, fulfillment, material handling: conveyors, sorters, palletizers, AS/RS, and AGV/AMR fleets. EtherNet/IP (Allen-Bradley / Rockwell conveyor & sorter PLCs), Profinet (Siemens material-handling lines), Modbus (VFDs / energy meters, with conveyor_vfd & agv_battery templates), OPC-UA (WMS/WCS gateways), and MQTT-Sparkplug (AMR / IoT telemetry) — plus the cross-protocol brain: predictive maintenance (pdm_forecast for conveyor-drive bearing/thermal trend), downtime triage, OEE/throughput, and alarm analysis. Use when the task mentions warehouse, 仓储, 物流, intralogistics, distribution center / DC, fulfillment, conveyor / 输送线, sorter / 分拣, palletizer, AS/RS / 立体库, AGV / AMR / 移动机器人, WMS / WCS, or material handling. Read-first; this edition's tool surface is read-only.